| To measure air humidity at home, start with a hygrometer. The EPA (the US Environmental Protection Agency) recommends keeping indoor humidity below 60%, ideally 30–50%. But if you see stains, mould or suspicious changes on the wall, a hygrometer isn't enough. Then you need moisture measurement in the materials themselves — with a material moisture meter (there are different technologies — with pins, pinless, special sensors — and what each one measures depends on the material and the manufacturer's scale) or, if you can't see anything, then the thermal camera can help, although it measures temperature rather than moisture. Remember: reliable diagnosis requires a suitable method, an understanding of each instrument’s limitations and technical interpretation. Hidden problems are IVM’s speciality.. |
Some household problems are manageable yourself. Others can become far bigger if left unchecked. Damp belongs in the second category. Understanding how it is measured is the first step towards assessing the problem.
This guide covers the essentials without unnecessary jargon.
What We Mean by «Measuring Damp» — It Isn't One Thing
There are two different forms of moisture to consider at home. Each needs a different measuring tool.
| Air Humidity | Moisture in Materials: Walls, Floors and Plaster |
| Water vapour in the room’s air | Water within building materials |
| Measured by a hygrometer as relative humidity (%) | Assessed using material moisture meters, either as a moisture percentage or a relative comparison, depending on the material and instrument. Not measured by a thermal camera. |
| Everyday sources include cooking, showering and breathing | Possible causes include leaks, water entry and inadequate insulation or waterproofing |
| Manage vapour production, ventilation and dehumidification. Cold surfaces or thermal bridges may also require changes to the building itself. | Find and address the underlying cause |
| Why the Difference Matters Many people buy a dehumidifier when mould appears. It reduces air humidity, but a hidden leak or water entering from outside can continue damaging the wall. The right instrument for the right measurement saves time and money. An experienced IVM engineer also assesses the pattern to help distinguish insulation-related condensation from a leak. |
Tool 1: A Hygrometer for Air Humidity
A hygrometer measures air humidity. It is widely available from electronics shops and online. A simple model around €20 is generally enough for ordinary home monitoring.
Air Humidity Levels
The EPA (the US Environmental Protection Agency) recommends, as a practical target, indoor humidity below 60%, ideally 30–50%, to limit the conditions that favour condensation and mould. The right level also depends on the temperature and the building's surfaces.
| Hygrometer Reading | What It Means | What You Do |
| Below 30% | Very dry air: possible dry skin or respiratory irritation | Consider whether humidification is needed |
| 30% – 40% | Dry air, common in winter with central heating | Usually no action needed — ventilation doesn't always improve things, as its effect depends on the outdoor conditions |
| 40% – 60% | Within the EPA limit (below 60%), ideal range 30–50% | Usually no humidity adjustment needed |
| 60% – 70% | Elevated: persistent levels can favour mould | Improve ventilation and check moisture sources |
| Above 70% | High: increased risk of mould and material damage | Dehumidify and investigate the cause |
Where to Put the Hygrometer
One reading cannot represent the whole home. Take readings in different rooms and record them.
- Bathroom: a major source of water vapour
- Kitchen: cooking and water use raise humidity
- Bedroom: conditions affect sleeping comfort
- Living room: a useful indicator of general indoor conditions
- Basement or storage room: often among the most affected spaces
| Practical Tip: Monitor the same room for 24–48 hours. A single reading immediately after a shower does not represent normal conditions. |
Tool 2: A Moisture Meter for Building Materials
A wall moisture meter (material hygrometer) measures the moisture inside the plaster, the brick or the floor. It's the tool used when you see stains or suspect a hidden problem.
Two common types are:
- Pin meters: two small pins contact or enter the surface, leaving small marks. Many are calibrated for wood; interpretation depends on the material and the instrument’s scale.
- Pinless meters: non-invasive scanning without puncturing the surface. They are useful for comparing suspected dry and wet areas of the same material. A relative reading should not be treated as a moisture percentage.
What to remember: handheld meters provide readings, not a diagnosis.
The reading tells you there's something to look into. It doesn't tell you where it's coming from or what needs fixing.
At IVM, the specialist engineer investigates the cause using professional equipment and a combination of methods. Then you discuss together the solution that suits your priorities and budget.
See how damp detection is done and what the visit includes →
Tool 3: Thermal Imaging — Clues Beyond Visible Marks
A thermal imaging camera (thermography) shows surface temperature differences. In suitable conditions, moisture can create a thermal anomaly. The camera detects that temperature pattern, not the moisture itself.
No digging, leaves no marks. Detects damp through the temperature drop caused by evaporation in walls, floors, roof terraces and ceilings — even if there's no visible damage yet.
| A Real Example: An Athens homeowner bought a dehumidifier after noticing a bathroom-wall stain. Three months later the stain had tripled. Thermal imaging gave specialist engineers useful clues but did not pinpoint the leak. Additional non-invasive methods located a leaking pipe 8 cm behind the tiles. Result: A small opening and a pipe repair by the building’s plumber, rather than demolishing or partly refurbishing the bathroom. |
When a Hygrometer Is Enough — and When You Need More
A hygrometer is useful for general monitoring. But an air humidity reading cannot answer every moisture question.
| Situation | Is a Hygrometer Enough? | What you need |
| Checking whether the air is dry or humid | Yes | A hygrometer is sufficient |
| A stain or discolouration on a wall | No | Wall moisture meter |
| Mould returning after cleaning | No | Professional investigation of the cause |
| An unexplained rise in the water bill | No | Thermal imaging and other checks for a possible hidden leak |
| Damp after rain or near pipework | No | Thermal imaging, supporting measurements and leak investigation |
| Checking walls before refurbishment | No | Investigate with thermal imaging and other methods before covering surfaces |
Signs That Need More Than an Air Humidity Reading
These signs may indicate a hidden source rather than air humidity alone.
- A stain that grows over time, even if you can't see water
- Mould returning within weeks of cleaning
- Blisters or peeling in the plaster or the paint
- A musty smell without a visible source
- An unexplained wet floor or dark, oil-like patch
- An unexplained increase in the water bill
| Take Care: If you recognise these signs, a hygrometer or moisture meter alone cannot provide the answer. Seek diagnosis by an experienced specialist engineer, rather than relying on a thermal camera alone. |
What to Do If You Find High Moisture — Step by Step
Measurement is only the first step. What follows determines whether you solve the problem or let it grow.
- Record the measurement: which room, at what height, what value.
- Check neighbouring spaces: the source may be away from the visible damage.
- Check nearby pipe routes, including water supply and drainage.
- Do not open walls before diagnosis: the cost of making good can multiply unnecessarily.
- Call a specialist engineer with thermal imaging and other instruments if damp persists or damage is visible.
When You Need Professional Diagnosis
DIY monitoring reaches its limit when moisture cannot be explained by ordinary indoor humidity. That is when an IVM specialist engineer can investigate.
Παίρνεις διάγνωση από κάποιον που δεν κερδίζει τίποτα από την επισκευή. Δεν κάνουμε επισκευές, άρα δεν έχουμε λόγο να βρούμε πρόβλημα που δεν υπάρχει, ούτε να καλύψουμε ανεπαρκή ή λάθος διάγνωση με εκτεταμένη επισκευή, που θα την πλήρωνες εσύ νομίζοντας ότι η δουλειά έγινε σωστά. Η διερεύνηση γίνεται από εξειδικευμένο μηχανικό, με επαγγελματική θερμοκάμερα και λοιπό εξειδικευμένο επαγγελματικό εξοπλισμό μη επεμβατικού ελέγχου, χωρίς να σπάσει τίποτα για να ψάξει. Τα όργανα όμως τα αγοράζει όποιος θέλει· το να ξέρεις τί σου δείχνουν θέλει χρόνια. Η IVM έχει 15 χρόνια εμπειρίας σε διάγνωση υγρασίας και εντοπισμό διαρροών σε κατοικίες και εμπορικά κτίρια στην Αθήνα και την Αττική (από το 2011), σχεδόν 20 σε εντοπισμό διαρροών και μη επεμβατική επιθεώρηση ηλεκτρομηχανολογικού εξοπλισμού στη βιομηχανία (από το 2006) και πάνω από 30 σε επισκευές και κατασκευές επιστημονικών οργάνων (από το 1994).
Clients include homeowners, blocks of flats and organisations such as Coca-Cola, EYDAP, Four Seasons, AVAX, Flisvos Marina and FAGE.
If you can't explain what's happening in your space, or if you've tried ways that didn't give a solution — such as a plumber with a thermal camera — it's time for the specialists. Before it's too late.
The fee
So that you know, before you break anything, what's wrong and which solution fits you, with a thorough non-invasive (non-destructive) check by a specialised engineer: the fee for water leak or damp detection is 410 € + VAT, with a customer satisfaction guarantee. That is: if for any reason your experience with IVM, from start to finish, didn't satisfy you, you ask for your money back, whenever you want (see our guarantee →). We explain the findings to you on the spot and discuss them together. We investigate one cause, wherever it takes us (what this means →). Your space stays as it was.
That's all for the visit. If there is an insurance policy, we contact its loss adjuster ourselves and send them whatever material they need to make use of the visit, at no extra charge. Only if you also want something in writing for your own reasons, which is optional, there is an extra fee: a technical report stamped by an engineer, 150 € + VAT, or an expert-witness report by a qualified engineer, 300 € + VAT (what each one includes →).
The fee applies from Voula to Kifisia, for homes up to 180 m². For business premises, homes over 180 m² and areas outside this zone, we start from the same fee and the specialised engineer will confirm it when they talk to you — before the appointment. Full details of our fees →
Tell us what you see or call us on 210 513 8501.
Frequently Asked Questions About Measuring Moisture at Home
What humidity level is normal at home?
The EPA (the US Environmental Protection Agency) recommends keeping indoor humidity below 60%, ideally 30–50%. Values constantly above 60% favour mould growth.
Where can I buy a hygrometer?
You can find a digital hygrometer in electronics shops, home-goods supermarkets and online. A reliable digital model is inexpensive — you don't need a costly device for normal use at home.
Can a hygrometer detect moisture in a wall?
No. A hygrometer only measures the humidity of the air in the room. To check whether there is moisture inside the wall, you need a wall moisture meter, not a thermal camera.
Will mould disappear if I reduce humidity?
It depends on the cause. If the mould is due solely to high air humidity (e.g. no ventilation), a dehumidifier helps. If the cause is a hidden leak or water ingress, a dehumidifier solves nothing — it's like bailing water out of a leaking boat: you may bail it out fast, faster than it comes in, but that doesn't mean it isn't coming in.
When should I call a specialist engineer about damp?
When you see stains that grow, mould that keeps coming back, plaster coming away or an unexplained rise in your water bill. These are signs that a dehumidifier won't fix — they need a professional diagnosis by a specialised engineer rather than a thermal camera inspection alone. A waterproofing contractor is another route if you want to avoid a separate investigation fee. Bear in mind the potential conflict of interest when the same person diagnoses the problem and sells the repair. You get the idea. 😉